🛑 Before commencing the project:
• Substrate Preparation & Cleanliness: Ensure the surface is sound, dry, and thoroughly cleared of contaminants and grease.
• Working Temperature: Ambient and substrate temperatures must be maintained strictly between +10 °C and +25 °C throughout installation and curing.
• Vinyl Sheet Flooring Outside Bathrooms: We advise against installing over vinyl flooring in general living areas. Vinyl is a soft substrate, posing high risks of indentation from furniture legs and concentrated point loads.
• Floor Layer Thickness: It is critical to keep coats thin. Over-applying finish coats results in a softer matrix with compromised compressive performance.
• Finish Coat Selection: Microdeck is standard for floor applications. Microfino can be applied in small zones, but on extensive floor plans, achieving visual uniformity becomes exceptionally difficult due to technique limitations.
• Substrate Preparation & Cleanliness: Ensure the surface is sound, dry, and thoroughly cleared of contaminants and grease.
• Working Temperature: Ambient and substrate temperatures must be maintained strictly between +10 °C and +25 °C throughout installation and curing.
• Vinyl Sheet Flooring Outside Bathrooms: We advise against installing over vinyl flooring in general living areas. Vinyl is a soft substrate, posing high risks of indentation from furniture legs and concentrated point loads.
• Floor Layer Thickness: It is critical to keep coats thin. Over-applying finish coats results in a softer matrix with compromised compressive performance.
• Finish Coat Selection: Microdeck is standard for floor applications. Microfino can be applied in small zones, but on extensive floor plans, achieving visual uniformity becomes exceptionally difficult due to technique limitations.
1. Substrate Preparation & Reinforcement
2. Build-up: Microcement
3. Sealing & Topcoats (Select Method)
Option 1: Topciment
Maximum Wear Resistance
Traditional specification using TT Presealer followed by hard-wearing two-component PU topcoat for elevated chemical resistance.
• TT Presealer: Apply 2 coats. Mask floor edges to prevent drops and runs; immediately back-roll drips on vertical faces. Allow to dry per technical instructions.
• Topsealer Dragon: De-nib lightly with 400-grit and roll 2 coats to form an impervious barrier against moisture ingress. Allow to cure naturally without forced air fans.
• Topsealer Dragon: De-nib lightly with 400-grit and roll 2 coats to form an impervious barrier against moisture ingress. Allow to cure naturally without forced air fans.
Option 2: DC Titan
Vapor Permeable
Rapid-drying, breathable sealer system optimal for basement slabs on ground and time-sensitive commercial programmes.
• Titan Presealer / Cream: Apply 1 coat diluted with 10–20% clean water. Cream is strongly recommended on floor areas.
• Titan Topsealer: Apply 2 coats of PU topcoat. Fast cross-linking and short recoat intervals.
• Titan Topsealer: Apply 2 coats of PU topcoat. Fast cross-linking and short recoat intervals.
4. Step-by-Step Workflow & Execution
💨 * Accelerate Drying Using Fans:
Drying intervals for primer and cementitious coats can be shortened using standard air circulators. Never use fan heaters; rapid forced evaporation weakens cement hydration and increases shrinkage cracking risks. Final topcoats must always cross-link naturally.
Drying intervals for primer and cementitious coats can be shortened using standard air circulators. Never use fan heaters; rapid forced evaporation weakens cement hydration and increases shrinkage cracking risks. Final topcoats must always cross-link naturally.