TT - Primapox 100 Barrier (ENG)
Two-component epoxy primer used as DPM and barrier coat before microcement.
Updated
by tomas martinsson
Guide / Epoxy Primer
Topciment — Primapox 100 Barrier
Instructions for two-component epoxy primer as a vapor barrier, damp-proof membrane, and blocking primer prior to microcement application.
🛑 Before You Begin:
• Substrate & Cleanliness: Ensure the surface is sound, dry, and free of dirt, oil, and grease.
• Substrate Must Be Level: Microcement is applied in very thin coats and will not conceal underlying substrate imperfections.
• Working Temperature: Ambient room and substrate temperatures must remain between +10 °C and +25 °C. Damp substrates are acceptable during application, but standing water must never be present.
• Ventilation: Ensure adequate workspace ventilation throughout the entire process.
• Substrate & Cleanliness: Ensure the surface is sound, dry, and free of dirt, oil, and grease.
• Substrate Must Be Level: Microcement is applied in very thin coats and will not conceal underlying substrate imperfections.
• Working Temperature: Ambient room and substrate temperatures must remain between +10 °C and +25 °C. Damp substrates are acceptable during application, but standing water must never be present.
• Ventilation: Ensure adequate workspace ventilation throughout the entire process.
1. Application Areas
2. Mixing & Working Time
🛑 Critical Mixing Precaution – Component B Spills:
It is critical to avoid spilling or splashing Component B onto floor or wall surfaces. The hardener will not cure independently, and microcement applied over contaminated areas will fail to cure properly. Always mix on protective floor covering or in a separate prep area.
It is critical to avoid spilling or splashing Component B onto floor or wall surfaces. The hardener will not cure independently, and microcement applied over contaminated areas will fail to cure properly. Always mix on protective floor covering or in a separate prep area.
3. Select Application Method
Method A: Vapor Barrier
Tiles & Floors
Stops telegraphing from underlying tile joints and protects bathroom floors around floor drains.
1. Application: Roll out an even coat with a short-pile roller or spread with a steel trowel.
2. Sand Broadcasting: Immediately broadcast dry quartz sand (0.3–0.8 mm) over the wet material to saturation (approx. 1 kg/m²).
3. Curing: Allow to cure for 24 hours. Sweep and thoroughly vacuum away all excess sand.
2. Sand Broadcasting: Immediately broadcast dry quartz sand (0.3–0.8 mm) over the wet material to saturation (approx. 1 kg/m²).
3. Curing: Allow to cure for 24 hours. Sweep and thoroughly vacuum away all excess sand.
Method B: Damp-Proof Membrane
Concrete & Rising Damp
Used to block rising ground moisture or residual moisture in concrete structures.
1. Coat 1: Roll out an even coat over the surface.
2. Sand Broadcasting: Immediately broadcast dry quartz sand (0.3–0.8 mm) into the wet material (approx. 1 kg/m²).
3. Curing: Allow to cure for 24 hours and vacuum away all excess sand.
4. Coat 2: Trowel a second coat of Primapox 100 Barrier with a steel trowel to ensure an impermeable seal.
2. Sand Broadcasting: Immediately broadcast dry quartz sand (0.3–0.8 mm) into the wet material (approx. 1 kg/m²).
3. Curing: Allow to cure for 24 hours and vacuum away all excess sand.
4. Coat 2: Trowel a second coat of Primapox 100 Barrier with a steel trowel to ensure an impermeable seal.
4. Next Steps: Substrate Prep & Base Coat
Once Primapox has cured and unbonded sand has been vacuumed away, install reinforcement mesh and apply the base coat:
Instructions: Substrate Preparation on Tiles ↗
Instructions: Fiberglass Mesh Guide ↗
Instructions: Microbase ↗
Documents & Technical Datasheets
📄 Technical Documentation: Primapox 100 Barrier
🛡️ Health & Safety Equipment & Tool Care:
• Protective Equipment: Product is chemically reactive and may cause skin irritation. Wear chemical-resistant gloves and safety goggles. Wear respiratory protection with organic vapor filters if ventilation is inadequate. Ensure good airflow.
• Tool Cleaning: Discard roller sleeves immediately after use. Clean trowels and steel tools immediately with acetone or solvent wipes before the epoxy begins to cure.
• Protective Equipment: Product is chemically reactive and may cause skin irritation. Wear chemical-resistant gloves and safety goggles. Wear respiratory protection with organic vapor filters if ventilation is inadequate. Ensure good airflow.
• Tool Cleaning: Discard roller sleeves immediately after use. Clean trowels and steel tools immediately with acetone or solvent wipes before the epoxy begins to cure.
How did we do?