Skip to main content

TT - Fiberglass Mesh & Reinforcement Guide (ENG)

Which fibreglass mesh to use with Topciment, how to fix it, how to run it into corners and what to do about air bubbles.

tomas martinsson
Updated by tomas martinsson
Installation Guide / Reinforcement

Fiberglass Mesh Selection & Reinforcement

Instructions for mesh selection, substrate preparation, corner detailing, and managing air pockets.

💡 Important before starting: The surface must be completely clean, planar, and dry before fitting the reinforcement mesh. Microcement only builds a few millimeters and cannot conceal underlying substrate imperfections.

1. Fiberglass Mesh Selection

Select the appropriate mesh specification based on the intended application:
• 50 g Mesh: The most pliable mesh, primarily utilized on walls, while also performing exceptionally well on worktops and smaller floor areas. Installed with a 1–5 cm lap joint. For larger floor areas, 58 g mesh is recommended instead.

• 58 g Mesh: The most widely specified mesh for larger floor plates and staircases. It can also be fitted to walls, though it handles somewhat stiffer. The mesh may be overlapped, but if microcement coats are skimmed ultra-thin, overlapping seams risk telegraphing. Therefore, fit the mesh butt-jointed edge-to-edge with high precision when working with thin builds.

2. Substrate Preparation & Fixing Method

The method of fixing the mesh depends on substrate porosity:
• On non-porous substrates (e.g. waterproofing membranes, vinyl flooring, tiles, or laminate): Roll adhere the mesh directly to the substrate using Primacem Plus.
• On porous substrates (e.g. concrete, plasterboard, or self-leveling screed): Saturate the substrate first with Primacem ABS or Acricem Resin. Once the primer has dried, roll adhere the mesh with Primacem Plus or embed it directly into the initial wet base coat.

3. Installation into Corners

In both internal and external corners, bring the mesh and cement neatly right to the junction without rounding or coving the corner.

Why? If the substrate or building structure moves, continuous mesh wrapped around internal corners can transfer shear stresses and cause cracks to migrate outward onto the flat wall plane. Stress fractures isolated strictly within internal corners are far simpler to remediate neatly with color-matched sealant or cement later.

4. Managing Air Pockets

It is completely normal for minor air bubbles to develop beneath the mesh during installation. Address them as follows:
• Carefully slit the bubble open with a utility knife during application, or grind them away retrospectively if small or missed initially.
• Sand the surface completely planar with 40-grit abrasives once the initial base coat has dried to eliminate all surface irregularities.

How did we do?

TT - Application on Waterproofing Membranes (ENG)

TT - Primer Selection Guide (ENG)