💡 About the Products:
• Forshield 2KWB: Two-component waterborne polyurethane sealer and the standard choice for walls and floors in residential environments. Provides a durable, satin-matte finish with high slip resistance.
• Forshield Ultra: A more durable and harder sealer formulated for worktops, tables, and commercial floors subject to stricter chemical and abrasion resistance requirements. Shares the same satin-matte sheen as 2KWB, but features a premium, heavy-duty formulation.
📱 Coverage & Mixing Ratio per m² (1 Coat):
• Forshield 2KWB: 50 g/m² (41.5 g Component A + 8.5 g Component B).
• Forshield Ultra: 50 g/m² (42.0 g Component A + 8.0 g Component B).
• Water Addition (Forshield 2KWB only): At higher ambient temperatures (above +20 °C) or on dark colors, up to 10% clean water by product weight may be added.
Always use the app to calculate material quantities and exact proportions for your project.
⚠️ Important Information Before Starting:
• Working Temperature: Material, substrate, and ambient air temperatures must remain between +10 °C and +25 °C.
• Warming Forshield Ultra: Must never be cold during application. Warm the bottle in a lukewarm water bath to +25–30 °C prior to mixing to optimize leveling and rolling characteristics.
• Storage & Shelf Life: Store frost-free. Shelf life is 12 months from production date in unopened original packaging.
• Pot Life / Open Time: Approximately 60 minutes at +20 °C after incorporating Component B.

1. Substrate Preparation

1.
Drying Time: Microcement must cure and dry for at least 18 hours before starting sealer application.
2.
Sand the Substrate: Sand the surface to achieve the desired finish profile. Do not leave floor surfaces excessively rough, as coarse textures collect dirt and become difficult to maintain.
3.
Vacuuming & Wiping: Vacuum and dry-mop the substrate meticulously. Wipe down the entire surface using a dry microfiber cloth. Residual sanding dust compromises adhesion, and on dark colors, dust trapped beneath the sealer produces a cloudy, whitish discoloration.

2. Mixing

🧪 Mixing Forshield 2KWB / Ultra:
1. Shake containers thoroughly before dosing. Add the entire specified amount of hardener (Component B) to the base (Component A).
2. Mix thoroughly using a mechanical paddle mixer at low speed (approx. 300–400 rpm).
3. Transfer the mixture into a separate, clean vessel and mix thoroughly once more.
4. Mix for at least 3 minutes in total. Incomplete mixing results in streaks, lap marks, or uneven sheen in the cured finish.

3. Application & Technique

Always use an 8 mm lint-free microfiber roller. Work wet-on-wet in 1–2 m² sections. Do not starve the roller—dry-rolling produces uneven, patchy lap lines:

1.
Horizontal Pass: Roll the sealer side-to-side applying firm pressure to ensure full wetting and saturation of the substrate.
2.
Vertical Cross-Pass: Immediately cross-roll the same section top-to-bottom at a 90° angle, maintaining steady pressure.
3.
Lay-off Pass: Tip off very lightly without downward pressure in a single, consistent direction to smooth out roller stipple.
4.
Maintain Wet Edge & Coat 2: Continue immediately from the wet edge so sections blend seamlessly wet-on-wet without puddles or joints. Allow to cure for at least 3 hours before applying Coat 2 in the same manner.
🛑 Health & Safety Equipment:
• Product may cause skin irritation. Wear suitable chemical-resistant nitrile gloves and safety goggles during all handling.
• Ensure adequate workspace ventilation during application and curing.
• Clean tools with water immediately after use while the sealer is still wet.
• For professional use only. Protect from freezing and keep out of reach of children.